Closed Gas Tight Trimode (UTI) Gauging Tape

Model: Closed Gas Tight Trimode (UTI) Gauging Tape Enhanced ‘CLOSED Gauging Systems
Product Type: MMC, tank management maintenance

Product Features

Featuring an ullage range of 15-35 meters, the system uses a new “PeeK” plastic sensor suitable for most chemical products and also refined petroleum products.

Surface Mount Technology
The sensor employs state-of-the-art SMT (Surface Mount Technology) and circuit enhancements that provide better long term reliability, more precise ullage level sensing, and improved oil-water “layer detection.”

The new compact model retains the same trouble-free, gas-tight, heavy duty mechanical design as its larger VLCC class brother. Both models now have built-in viewing window wipers.

“Intrinsically Safe”
All models are also approved as “Intrinsically Safe” and as Class 1, Div. 1 gas groups’ C&D equipment.

Product Specifications

Specifications:
Display Readable Temperature Range

*Reading Limit Due to 3-1/3 Digit LCD Display on °F Range

°F = -40° to 199.9°*

°C = -40° to 150.0°

Guaranteed Temperature Calibration Range 32°F to 190°F

(0°C to 88°C)

Accuracy Over Calibration Range ±0.2°F (±0.1°C)
Accuracy Linear Measurements ±1/8” (±2.0 mm), Plus ±0.1%
of Total Tape Length, worst case
Minimum Detectable Tank Bottom Liquid Level 3/8” (10mm)
Minimum Detectable Floating Product Level 1/8” (3mm)
Batteries for Intrinsically Safe Operation Only (Supplied) Duracell MN1604
Battery Drain (Temperature Mode) 1.3 ma (In Air)

2.6 ma (In Fluid)

Display 3-1/2″ Digit Liquid Crystal

Display 1/2” Character Height

Operating Temperature Limit of Liquid Crystal Display -40°F to 176°F

-40°C to 80°

Storage Temperature Limits -67°F to 185°F

-55°C to 85°C

Available Tape Length, *Single Face Scales 50 ft (15 m)

65 ft (20 m)

75 ft (25 m)

100 ft (30 m)

*100 ft (10ths & 100ths)

35m

Hazardous Environments Certified Intrinsically Safe

BASEEFA/SIRA,
Gas Groups C & D